Reuse an existing concrete footing with a properly engineered anchor bolt solution.
Damaged, broken, missing, or misaligned light pole anchor bolts do not always require a new concrete footing. Light Pole Systems offers Anchor Bolt Adapter and drill-and-epoxy solutions for qualifying applications.
Light pole anchor bolt problems often appear when replacing an existing pole, installing a different pole on an existing footing, or dealing with damaged hardware.
Not every light pole anchor bolt problem requires the same repair. The right solution depends on the condition of the existing anchor bolts, the concrete footing, the required bolt circle, the replacement pole specifications, and the project’s EPA and structural load requirements.
Light Pole Systems recommends evaluating the available options in this order.
Use first when the existing anchor bolts are still usable but the replacement pole has a different bolt pattern.
Consider an adapter when:
Use when existing anchor bolts cannot be reused or the required adjustment exceeds the Anchor Bolt Adapter limits.
Consider a drill-and-epoxy system when:
Use when the existing foundation is not suitable for reuse or cannot support the required loads.
Footing replacement may be necessary when:
Final selection should consider the existing footing, anchor condition, bolt circle, pole specifications, EPA load, and project engineering requirements.
Light Pole Systems offers two drill-and-epoxy retrofit systems for creating new anchor locations in existing concrete footings. The AT.75 uses 3/4-inch all-thread rod, while the AT1 uses 1-inch all-thread rod for larger applications.
Not sure which kit applies? Compare AT.75 vs. AT1 below.
Both systems are designed for drill-and-epoxy light pole anchor retrofit applications, but they differ in rod diameter, embedment, and bolt-circle range. Use the light pole manufacturer’s anchor-bolt requirements and project conditions to determine which system applies.
AT.75 is commonly used where 3/4-inch anchor bolts are specified, while AT1 is used where 1-inch anchor bolts are required. Final selection should follow the pole manufacturer’s specifications, bolt circle, footing conditions, EPA load, and engineering requirements.
The published AT.75 and AT1 engineering is based on specific bolt-circle ranges, minimum embedment, edge distance, and properly reinforced concrete. Applications outside these published conditions may require additional engineering.
Published Tables:
7"
8"
9"
10"
For bolt circles larger than 10″, use the 10″ table as the published reference. Smaller bolt circles may require additional engineering.
Published Tables:
9"
10"
11"
12"
For bolt circles larger than 12″, use the 12″ table as the published reference. Smaller bolt circles may require additional engineering.
Concrete Strength
minimum
Minimum Edge Distance
AT.75 Embedment
AT1 Embedment
Published AT.75 and AT1 load tables presume properly reinforced concrete with a minimum compressive strength of 4,000 PSI.
Lower-strength concrete, smaller bolt circles, unusual footing conditions, or project loads outside the published tables may still be possible, but additional engineering may be required. Light Pole Systems can help evaluate these applications.
The AT.75 and AT1 systems create new light pole anchor locations in an existing concrete footing by drilling new holes, cleaning the holes, installing structural anchoring epoxy, and inserting fully threaded rods to the required embedment depth.
Watch the Light Pole Systems video for a practical overview of the drill-and-epoxy installation process, then use the steps below as a quick reference.
Based on the Light Pole Systems installation guidance for this system:
70°F and above
24 hours
60°F
48 hours
50°F
72 hours
40°F
192 hours
Cure time is temperature-dependent. Installation should follow the current Simpson Strong-Tie SET-3G requirements and the applicable project engineering before the anchors are loaded.
Confirm the replacement light pole manufacturer’s required bolt circle and mark the new anchor locations on the existing concrete footing.
The new anchor locations must also maintain the required edge distance and match the applicable AT.75 or AT1 engineering requirements.
Drill each new anchor location to the required diameter and embedment depth for the selected system.
Both systems use a minimum edge distance of 1-3/4 inches under the published engineering conditions.
Remove concrete dust and drilling debris from each hole before installing the epoxy.
Proper hole preparation is important for the anchoring epoxy to bond correctly to the concrete and fully threaded rod. Follow the current epoxy manufacturer’s installation procedures for hole cleaning and preparation.
Dispense the specified structural anchoring epoxy into the prepared holes and insert the fully threaded rods to the required embedment depth.
Fully threaded rod is used because the epoxy bonds around the threads along the embedded portion of the rod. A partially threaded rod should not be substituted for the specified all-thread rod.
Do not load the anchors or mount the light pole until the epoxy has reached the required cure time for the jobsite temperature.
The drill-and-epoxy method is intended to create new anchor locations in an existing concrete footing. These new anchors use fully threaded rod rather than traditional embedded J- or L-style anchor bolts. The existing footing, concrete condition, bolt circle, edge distance, embedment depth, pole specifications, and structural load requirements should all be evaluated before installation.
The published AT.75 and AT1 load charts are based on specific installation conditions, footing characteristics, bolt-circle dimensions, and structural requirements. Projects that fall outside those conditions may require additional engineering before installation.
Additional engineering may be needed when the existing concrete is below 4,000 PSI, the bolt circle is smaller than the published range, the required loads exceed the published tables, footing conditions are unusual, or another project condition falls outside the standard AT.75 or AT1 engineering.
The correct kit depends on the light pole manufacturer’s anchor-bolt requirements, pole size, bolt circle, footing conditions, and structural load requirements. As a general guideline, AT.75 is used for applications requiring 3/4-inch anchor bolts, while AT1 is used where 1-inch anchor bolts are specified.
ANCHOR BOLT
General application guidance: 3/4-inch anchor bolts are commonly used on poles up to approximately 4 inches in diameter and 25 feet in height, depending on the manufacturer and project loads.
ANCHOR BOLT
General application guidance: 1-inch anchor bolts are commonly used on poles approximately 5 inches in diameter and larger, up to around 40 feet in height, depending on the manufacturer and project loads.
Do not select AT.75 or AT1 based on pole height alone. Confirm the manufacturer-specified anchor-bolt diameter, bolt circle, EPA/load requirements, and footing conditions before choosing the kit.
Light pole anchor bolt problems often appear when replacing an existing pole, installing a different pole on an existing footing, or dealing with damaged hardware.
Traditional J- or L-style anchor bolts that are embedded in concrete generally cannot be simply removed and replaced. Replacing them typically requires installing a new concrete footing or removing and rebuilding a portion of the existing footing with new reinforcement and anchor bolts.
For qualifying applications, Light Pole Systems may instead recommend an Anchor Bolt Adapter or a drill-and-epoxy retrofit system using fully threaded rod.
Traditional embedded anchor bolts are installed before the concrete cures, so they cannot be installed afterward in the same manner.
However, new light pole anchor locations can be created in an existing concrete footing using a properly engineered drill-and-epoxy system with fully threaded rod.
Yes. For this method, fully threaded rod is drilled and epoxied into the existing concrete footing.
Fully threaded rod is required because the anchoring epoxy bonds along the threaded surface of the rod. A partially threaded traditional anchor bolt should not be substituted for the specified all-thread rod.
For the published Light Pole Systems AT engineering:
Applications outside the published conditions may require additional engineering.
The required drill-hole diameter is 1/8 inch larger than the threaded rod diameter:
The published AT.75 and AT1 engineering is based on properly reinforced concrete with a minimum compressive strength of 4,000 PSI.
Lower-strength concrete may still be suitable for some projects, but additional engineering may be required before the standard AT load charts can be applied.
AT.75 is designed for bolt circles of 7 inches and larger, with published tables for 7″, 8″, 9″, and 10″ bolt circles.
For bolt circles larger than 10″, the 10″ table is used as the published reference.
AT1 is designed for bolt circles of 9 inches and larger, with published tables for 9″, 10″, 11″, and 12″ bolt circles.
For bolt circles larger than 12″, the 12″ table is used as the published reference.
Smaller bolt circles may be possible in some applications but may require additional engineering.
Cure time depends on the jobsite temperature.
Installation should follow the current Simpson Strong-Tie SET-3G requirements and applicable project engineering before the anchors are loaded.
The correct kit should be based primarily on the anchor-bolt diameter specified by the light pole manufacturer and the project’s structural requirements.
As a general guideline:
Three-quarter-inch anchor bolts are commonly used on poles up to approximately 4 inches in diameter and 25 feet in height. One-inch anchor bolts are commonly used on poles approximately 5 inches in diameter and larger, up to around 40 feet in height.
Pole height alone should not be used to select the kit. Bolt circle, EPA load, footing conditions, and manufacturer requirements must also be considered.
The Anchor Bolt Adapter should generally be evaluated first when the existing anchor bolts are still structurally usable.
For 3/4-inch anchor bolts, the ABA.75 is typically considered when the required bolt-circle adjustment is approximately 4.4 inches or less and the project remains within the adapter’s EPA rating.
For 1-inch anchor bolts, the ABA1 is typically considered when the required bolt-circle adjustment is approximately 5 inches or less and the project remains within the adapter’s EPA rating.
When the required adjustment exceeds those limits, the adapter load rating is exceeded, or the existing anchor bolts cannot be reused, the AT.75 or AT1 drill-and-epoxy system may be the more appropriate solution.
The drill-and-epoxy systems may be used for qualifying projects involving:
Installing the AT.75 and AT1 Drill-and-Epoxy Anchor Bolt Kits requires proper drilling, hole-cleaning, epoxy application, and installation equipment.
Recommended tools and materials include:
Some specialized equipment, including the nylon hole-cleaning brush and epoxy dispensing tool, may be available directly from Light Pole Systems.
For proper installation, follow the product instructions and applicable engineering requirements.
Light Pole Systems’ AT.75 and AT1 Drill-and-Epoxy Anchor Bolt Kits simplify light pole anchor bolt replacement by bringing together the necessary threaded rods, hardware, epoxy, and published engineering load tables in one convenient package.
Instead of sourcing individual components and researching their compatibility separately, contractors can reference the published specifications to determine whether a kit is suitable for their project.
Key advantages include:
Both kits are designed to help contractors streamline anchor bolt replacement while following the applicable installation instructions and engineering requirements.
Need additional information? Review our Light Pole Replacement Tools Guide for more information about equipment used during light pole replacement projects.
Use these guides and product pages to compare repair options, verify bolt patterns, confirm anchor-bolt sizing, and learn more about installing new anchors in an existing concrete footing.
When the existing anchor bolts are still structurally usable but the replacement light pole has a different bolt pattern, an Anchor Bolt Adapter may allow the existing footing and anchors to remain in place.
Review the drill-and-epoxy process for creating new anchor locations in an existing concrete footing, including preparation, drilling, cleaning, epoxy installation, and threaded-rod placement.
Learn how to measure light pole bolt-circle and bolt-square dimensions before selecting a replacement pole, Anchor Bolt Adapter, or drill-and-epoxy retrofit solution.
Review common light pole anchor-bolt sizes and the factors that affect anchor selection, including pole specifications, bolt diameter, and project requirements.
Every light pole replacement project is different. Light Pole Systems can help review the existing footing, anchor-bolt condition, required bolt circle, replacement pole specifications, and structural requirements to determine whether an Anchor Bolt Adapter, AT.75, AT1, or another solution should be evaluated.
Choose Light Pole Systems, Inc. for dependable, high quality components built to last. With expert engineering, custom solutions, and unmatched durability, we’re here to support your project from start to finish, stronger, smarter, and ready for any challenge.
information